SYBR Green PCR SuperMix

Product name: SYBR Green PCR SuperMix
Introduction: SYBR Green PCR SuperMix is an optimized 2x real-time PCR master mix containing HotStarTaq DNA Polymerase, SYBR Green® fluorescent dye, dNTP and Mg2+. In addition, the balanced K+ and NH4+ ion ratios in the buffer promote specific primer annealing. To ensure a highly sensitive and specific PCR reaction, the reaction can be initiated by simply adding the primer and cDNA template to the ready-to-use PCR master mix. The unique PCR buffer ensures sensitive qPCR on all real-time PCR instruments without optimization.
Advantage: 1.Quickly get results, saving up to 50% of the time
2.Optimized ready-to-use master mix for rapid PCR reactions
3.Accurate detection of various starting amounts of templates, stable amplification, quantitative results with high repeatability
4.Balanced K+ and NH4+ ion ratios, as well as stand-alone ROX Reference Dye packaging for all real-time PCR instruments
Add to Wishlist
Add to Wishlist

Description

Catalog No. Specification SYBR Green PCR SuperMix 50x ROX Dye RNase-Free 

ddH2O

  

Storage/Shelf life

100EQ 20μL×500 rxns 4 x 1.25mL 1mL 4 x 1.25mL -20℃/one year

Advantage
1) Quickly get results, saving up to 50% of the time
2) Optimized ready-to-use master mix for rapid PCR reactions
3) Accurate detection of various starting amounts of templates, stable amplification, quantitative results with high repeatability
4) Balanced K+ and NH4+ ion ratios, as well as stand-alone ROX Reference Dye packagingforall real-time PCR instruments

Introduction
SYBR Green PCR SuperMix is an optimized 2x real-time PCR master mix containingHotStarTaq DNA Polymerase, SYBR Green® fluorescent dye, dNTP and Mg 2+ . In addition, thebalanced K + and NH4 + ion ratios in the buffer promote specific primer annealing. To ensureahighlysensitive and specific PCR reaction, the reaction can be initiated by simply adding theprimerandcDNA template to the ready-to-use PCR master mix. The unique PCR buffer ensures sensitiveqPCRon all real-time PCR instruments without optimization.

Kit Components

Component Character Advantage
  

 

 

HotStarTaq DNA Polymerase

Heating at the pre-denaturation temperature for 30s will completely inactivate the blocking antibody and 

release the DNA polymerase activity.

  

Effectively suppresses non-specific amplification caused by primer annealing

  

 

 

SYBR Green qPCR Buffer

  

 

Suitable for all real-time PCR instruments

qPCR run time is reduced by 50%, results are obtained faster, and more PCR reactions can be completed in one 

day

  

 

 

 

SYBR Green I dye

  

 

 

Strong fluorescence signal when combined with DNA duplex

High sensitivity amplification. It provides a wide-area linear range with a Ct value of 5-35 and a high sensitivity for single-digit copy detection, and is 

suitable for melting curve analysis.

  

 

ROX dye

  

Calibration of fluorescent signals on ABI and Agilent PCR machines

Calibration of PCR machines that 

require ROX dyes does not affect PCR reaction results

Kit principle

SYBR Green PCR SuperMix provides a wide range of specific, sensitive assays for standard and rapid PCR machines. The SYBR Green I dye in the master mix can analyze multiple target nucleic acids without the need to synthesize sequence-specific probes. The special fast PCR buffer can greatly shorten the denaturation, annealing and extension time, and has good applicability to complex templates, templates with more PCR inhibitor residues (such as soil and fecal DNA),and long-range amplification. In addition,HotStarTaq DNA Polymerase can be activated by heating at 95℃ for 30sec,requiring a strict hot start to avoid nonspecific products.

Kit application

SYBR Green PCR SuperMix Can be used for gene expression analysis of cDNA, plasmids, gDNA,absolute quantitative analysis. It is suitable for various real-time PCR machines, including ABI, Bio-Rad, Eppendorf, Roche and Agilent PCR machines.

Attention

1.   Template

cDNA: For two-step quantitative qPCR, Use 10μL of cDNA reverse transcribed from total RNA (10pg to 1ng).

In the 20 μL reaction system, the amount of cDNA template used is generally not more than 100 ng.. It should be noted that when detecting high-abundance genes in undiluted cDNA, the Ct value in quantitative PCR results may be too low, which may affect the accuracy of quantification. Gradient dilution of the cDNA template results in more accurate results.

Plasmid and genomic DNA: 100pg to 1ng of genomic DNA or 10-107 copies of plasmid DNA can be used in a 20μL system.

1.   Transportation and storage

  • Ice bag, dry ice
  • Store at -20 ℃ in the dark. This product contains the fluorescent dye SYBR® Green I. When storing or formulating the reaction system, avoid strong light. Please mix it upside down before
  • For your safety and health, please wear a lab coat and wear disposable gloves when performing the

Reaction System

A reaction system as described below was established. To perform multiple reactions, prepare a premix of the common components, add a suitable volume to each tube or well, and then add a special reaction component (eg, template)

Composition 96 wells 384 wells Final Concentration
50µL reaction system 20µL reaction system 10µL reaction system ——
2 x SYBR Green PCR Master Mix 25µL 10µL 5µL 1 x
PCR Forward Primer (10 µM) 1µL 0.4µL 0.2µL 0.2µM
PCR Reverse Primer (10 µM) 1µL 0.4µL 0.2µL 0.2µM
Template
*50 x ROX Dye(Optional) 1µL 0.4µL 0.2µL 1x
RNase-Free ddH2O to 50µL to 20µL to 10µL ——
  1. It is recommended to use a 20μL or 50μL system to ensure the validity and repeatability of the amplification of the gene of
  2. Cover or seal the reaction tube/PCR plate and mix gently. It can be centrifuged slightly to ensure that all components are at the bottom of the
  3. Place the reaction system in a real-time PCR instrument, collect data and analyze the results. Set up your PCR instrument as shown in the table Optimum temperature

The incubation time can be determined by the specific situation.

ROX dye

The fluorescent signal in the reaction system can be standardized by adding a ROX dye to the reaction system according to the selected instrument. The table below lists the amount of ROX required per unit of operation (per 50μL of reaction system):

Instrument The amount of ROX required for each 50 μL system reaction
ABI7300、7900HT、StepOne etc. 5µL
ABI7500、7500Fast、 ViiA7、Stratagene Mx3000™、Mx3005P 

™ and Mx4000™ etc.

 

1µL

Roche、Bio-Rad,Eppendorf etc. No need to add

Two-step amplification procedure:

Stage Number of cycles Temperature Time
Pre-denaturation 1x 95℃ 30 sec
Denaturation   

35-40x

95℃ 5 sec
Annealing/extension 60℃ 30 sec
Melting Curve stage

Three-step amplification procedure:

Stage Number of 

cycles

Temperature Time
Pre-denaturation 1x 95℃ 30 sec
Denaturation   

35-40x

95℃ 5 sec
Annealing 50-60℃ 30 sec
extension 72℃ 30 sec
Melting curve analysis(Melting Curve stage)

Reviews

There are no reviews yet.

Be the first to review “SYBR Green PCR SuperMix”
All fields marked with an asterisk (*) are required

X