Link Biotech

A-1/264A Paschim Vihar, New Delhi - 110063

Human REN(Renin) ELISA Kit

SKU Code LBEK-093H
Species Human
Sensitivity 18.75pg/ml
Detection-range 31.25-2000pg/ml
Size 96 T | 48 T
Price POR
Brand Link Biotech
SKU: LBEK-093H
Human REN(Renin) ELISA Kit
UniProt ID P00797
Sample Type Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Detection Method Sandwich ELISA, Double Antibody
Detection Wavelength OD450
Reaction Duration 4 hours
Storage 2-8°C(Sealed), Don't cryopreserve.
Specificity Specifically binds with REN , no obvious cross reaction with other analogues.

Additional information

sensitivity

18.75pg/ml

detection-range

31.25-2000pg/ml

Brand

Link Biotech

This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)

Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.

STD.(pg/ml) OD-1 OD-2 Average
0 0.084 0.088 0.086
31.25 0.128 0.135 0.131
62.5 0.211 0.222 0.215
125 0.301 0.317 0.308
250 0.489 0.514 0.499
500 0.787 0.827 0.803
1000 1.221 1.283 1.246
2000 1.991 2.093 2.032
EH0268 Standard Curve Image

Add a certain amount of REN into the sample. Calculate the recovery by comparing the measured value with the expected amount of REN in the sample.

Sample Type Recovery Range(%) Average(%)
serum(n=10) 97-101 100
EDTA plasma(n=10) 95-102 99
Heparin plasma(n=10) 96-102 99

Dilute the sample with a certain amount of REN at 1:2, 1:4 and 1:8 to get the recovery range.

Sample Type 1:2 1:4 1:8
serum(n=10) 91-105% 90-97% 92-99%
EDTA plasma(n=10) 90-105% 90-98% 91-96%
Heparin plasma(n=10) 91-104% 89-94% 90-99%

Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.

Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.

Item Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (pg/ml) 59.17 241.4 970.7 59.65 250.1 983.8
Standard deviation 2.69 13.3 53.97 3.33 14.53 57.85
CV(%) 4.55 5.51 5.56 5.59 5.81 5.88

Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.

ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months 2-8°C for 12 months
Average(%) 80 95-100 85-98