Malondialdehyde (MDA) Elisa Kit

SKU Code LBRB-026U
Species Universal
Sensitivity 9.15 ng/mL
Detection Range 31.25-2000 ng/mL
Size 96 T | 48 T
Price $ 365 | $ 265
SKU: LBRB-026U

Description

MDA(Malondialdehyde) ELISA Kit - Product Details
Alternative Names MDA
Uniprot ID N/A
Standard 2000 ng/mL
Detection method Competitive
Sample type Serum, Plasma and Other biological fluids
Reaction time 1.5H
Research Area Metabolic pathway;Hepatology;Hormone metabolism
Test Principle
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with MDA. Standards or samples are added to the appropriate micro ELISA plate wells then with a biotin-conjugated antibody specific to MDA. Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of MDA in the samples is then determined by comparing the OD of the samples to the standard curve.

Additional information

Sensitivity

9.15 ng/mL

Detection Range

31.25-2000 ng/mL

Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(pg/mL) OD
2000.00 0.195
1000.00 0.331
500.00 0.546
250.00 0.880
125.00 1.308
62.50 1.700
31.25 2.076
0.00 2.516

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(ng/mL) 39.37 84.03 561.80 40.98 62.89 699.30
Standard deviation 4.20 9.27 29.02 5.22 11.54 36.12
C V (%) 5.37 4.31 2.75 5.80 4.27 4.62

Rate of Recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Avg Recovery(%)
Serum (n=8) 88-99 93
EDTA plasma (n=8) 86-98 92
Cell culture media (n=8) 82-98 87

Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 83-94 85-93 87-99
Average (%) 90 91 95
1:4 Range (%) 80-92 85-93 82-96
Average (%) 81 86 86
1:8 Range (%) 86-102 80-96 85-96
Average (%) 96 90 91
1:16 Range (%) 87-103 93-106 87-101
Average (%) 87 103 90